Respiratory protection and Masks
Effective respiratory protection to filter contaminants and reduce risks in professional environments across Quebec and Canada.
Effective respiratory protection to filter contaminants and reduce risks in professional environments across Quebec and Canada.
Learn more
Masks and respiratory protection: how to choose the right equipment
In a clinic, a care facility or a workplace, respiratory exposure risks are not all the same. Some situations call for a barrier against splashes and sprays, while others require a respirator designed to filter airborne contaminants.
That is why choosing a respiratory protection mask should never come down to comparing prices or how products look.
A Level 2 medical mask, an N95 respirator and a P100 filter serve different purposes. CPR pocket masks and oxygen delivery masks also belong to distinct categories.
At Cardio Choc, we offer disposable medical masks, 3M N95 respirators, P100 filters and cartridges, as well as CPR pocket masks and various respiratory accessories.
Here is how to understand these differences, check product features and choose the equipment suited to your environment.
What are the different types of masks and respiratory equipment?
The equipment in this category can be divided into three main families.
Type of equipment — Main function — Use to consider
- Medical procedure mask — Main function: Barrier against certain splashes and droplets; Use to consider: Patient care, professional settings
- N95 respirator — Main function: Filtration of airborne particles, with a proper facial seal; Use to consider: Specific occupational exposures
- P100 filter or cartridge — Main function: Particle filtration on a compatible respirator; Use to consider: Industrial work and other assessed exposures
- Combination P100/gas/vapour cartridge — Main function: Protection against certain specified contaminants; Use to consider: Environments with particular contaminants
- CPR pocket mask — Main function: Barrier during certain rescue breaths; Use to consider: First aid and emergency response
- Resuscitation bag-valve mask — Main function: Ventilation assistance according to skills and protocols; Use to consider: Medical or specialized interventions
- Oxygen mask or nebulizer — Main function: Medical delivery of a gas or treatment as indicated; Use to consider: Oxygen therapy and respiratory care
A resuscitation or oxygen therapy mask is not a filtering respirator designed to protect the worker against airborne contaminants.
This distinction is essential to making the right purchase.
Level 1 and Level 2 medical masks: what is the difference?
Disposable medical masks are used in various care and service environments.
They can help reduce the spread of certain droplets and provide protection against splashes, depending on their characteristics.
Cardio Choc offers Level 1 and Level 2 medical masks, among others, in packs of 500.
Level 1 medical mask
Level 1 is a performance category generally intended for situations where the risk of liquid splashes is lower.
It may be suitable for certain tasks when the facility's protocol calls for this level of protection.
However, you should not assume that a Level 1 mask is appropriate for all medical procedures.
Level 2 medical mask
Level 2 generally corresponds to greater resistance to liquid penetration than Level 1, under the applicable performance tests.
It may be appropriate in certain environments where the risk of splashes is greater.
Level comparison
Criterion — Level 1 — Level 2
- Resistance to liquid splashes — Level 1: Lower performance level; Level 2: Higher performance level
- Use — Level 1: According to risks and protocols; Level 2: According to risks and protocols
- Tight facial fit — Level 1: Not guaranteed; Level 2: Not guaranteed
- Replaces an N95 respirator — Level 1: No; Level 2: No
- Cardio Choc packaging — Level 1: 500 units; Level 2: 500 units
Levels must be interpreted according to the standard actually declared for the product. It is important to check its technical data sheet rather than relying only on its commercial name.
Why doesn't a medical mask replace an N95?
A medical procedure mask is generally not designed to provide the same facial seal as a fitted respirator.
Gaps may remain between the mask and the face.
An N95 respirator, when properly selected and fitted, is designed to limit the inhalation of certain airborne particles.
The equipment must therefore be selected according to the actual risk.
In situations where fitted respiratory protection is required, a simple Level 2 medical mask must not be considered equivalent to an N95.
3M N95 8210 respirator: particle filtration
The 3M N95 8210 is a disposable filtering respirator approved by NIOSH.
It is designed to filter at least 95% of the particles used in the N95 classification test conditions.
Cardio Choc offers it in boxes of 20.
Main features
The 8210 model features:
- N95-class filtration.
- A cup-shaped design.
- Two head straps.
- An adjustable nose clip.
- A foam strip at the nose.
- Lightweight construction.
The model can be used in certain occupational environments when its characteristics match the contaminants present and the conditions for selection, fit and use are met.
Discover the 3M N95 8210 respirator – 20 units.
What does N95 mean?
The N95 classification refers to a filtering respirator that achieves a minimum efficiency of 95% against the particles used in certification tests.
The letter N indicates that this class is not resistant to oil aerosols.
This classification does not mean the respirator filters all gases, vapours or chemicals.
Nor does it guarantee adequate protection when the mask does not fit the face properly.
N95 mask with or without a valve: which should you choose?
Some disposable respirators have an exhalation valve.
Cardio Choc also carries the 3M 8210V N95 with valve, available in boxes of 10.
The benefit of the valve
An exhalation valve can reduce heat and moisture buildup under certain conditions of use.
It can also improve breathing comfort for some users.
The limitations
The presence of a valve does not automatically change the filtration rating for inhaled particles.
However, protection against exhaled emissions released into the environment must be assessed separately, depending on the design of the device and the requirements of the setting.
In some care environments, a respirator without a valve may be preferred when control of exhaled emissions is necessary.
Check the model and your facility's rules.
Which model should you choose?
The 8210 and 8210V should not be chosen based only on perceived comfort.
Consider the exposure, the fit, the working conditions and the applicable protocols.
P100 2091 filter: for which hazards?
3M P100 2091 filters are designed for use with compatible reusable respirators.
They help reduce exposure to certain solid and liquid particles, including those containing oil, depending on their approval.
Cardio Choc offers the 2091 filters as a pair.
What does P100 mean?
The P100 classification corresponds to a very high level of filtration against particles under the applicable test conditions.
P100 filters are also resistant to oil-based particles, which sets them apart from N95 filters.
However, they are not designed on their own to filter all gases and vapours.
When should you consider P100?
Filters in this category can be used for certain tasks that expose workers to particulate contaminants, including in manufacturing, metalworking and other industrial environments.
The choice must depend on the specific contaminant, its concentration and the respiratory protection program.
Check the compatible respirator
2091 filters must be used with respirators approved for this part number.
They are not universal and cannot be attached to just any mask.
Check the connection systems and the approved combinations.
See Cardio Choc respiratory protection products.
3M 60926 combination cartridge: particles, gases and vapours
The 3M 60926 is a combination cartridge that pairs P100 filtration with protection against certain families of gases and vapours, depending on its certification.
Cardio Choc offers it as a pair.
Which contaminants are covered?
The Cardio Choc product page mentions certain categories of organic vapours, acid gases and other specific substances.
However, a cartridge does not automatically protect against every chemical in those categories.
Check the exact indications, permitted concentrations and use limits published by 3M.
Compatibility with 3M respirators
The 60926 product page indicates compatibility with certain 3M half-face and full-face respirators in the 6000, 7000 and FF-400 series fitted with the appropriate connectors.
It is important to confirm the exact respirator model.
Do not use in an unknown hazardous atmosphere
Filtering respirators with cartridges do not produce oxygen.
They must not be used in oxygen-deficient environments or in concentrations that are immediately dangerous to life or health.
In these situations, a specialized assessment and an appropriate breathing apparatus are required.
N95 or P100: how do you choose?
These ratings are sometimes compared as if P100 were simply a more powerful N95.
In reality, the choice depends on several factors.
Criterion — N95 — P100
- Minimum efficiency in tests — N95: 95%; P100: 99.97%
- Resistance to oil-based particles — N95: No; P100: Yes, depending on classification
- Common form — N95: Disposable respirator; P100: Filter for a reusable respirator
- Gas and vapour filtration — N95: No; P100: No, unless an appropriate combination cartridge is used
- Facial fit — N95: Essential; P100: Essential with a fitted respirator
- Selection based on risks — N95: Mandatory; P100: Mandatory
A P100 filter alone is not a complete device.
It must be paired with a compatible respirator and used in accordance with its certification.
Fit testing: why is it important?
For a fitted respirator, the quality of the filtration is not enough.
The respirator must also seal properly against the face.
A poor fit can allow contaminated air to enter through the gaps between the mask and the skin.
Fit test
A fit test determines whether a respirator model and size suit a given user.
At work, fitted respiratory protective equipment requires oversight that complies with the applicable requirements.
The Canadian Centre for Occupational Health and Safety recommends, among other things, repeating fit tests every two years, or sooner when certain changes affect facial shape or equipment.
Seal check
A seal check must also be performed each time the respirator is used, following the manufacturer's instructions.
It does not replace the initial fit test.
Beards and seal
Facial hair in the contact area can compromise the seal of a fitted respirator.
The user must follow the requirements of their respiratory protection program.
CPR pocket masks: another form of protection
The collection also includes pocket masks for rescue breaths during CPR.
These products are not used to filter ambient air the way an N95 does.
They create a barrier between the rescuer and the person being helped, depending on their design.
CPR pocket mask with O2 inlet and case
Cardio Choc offers an adult pocket mask that includes a valve, a filter and an oxygen inlet.
The hard case version also has a holding strap.
This type of product can be part of a trained first aider's equipment.
Discover the CPR pocket mask with O2.
CPR pocket mask with valve and soft pouch
Another model is available with a non-return valve, a filter and a storage pouch.
It can be a good choice when space is limited in a first aid kit.
See the CPR pocket mask with O2 and valve.
A CPR mask is not a respirator
It is important not to confuse the functions.
The pocket mask is a ventilation assist device, used in resuscitation situations by a trained person.
It does not protect the user against industrial dust or hazardous gases.
Bag-valve masks, nebulizers and O2 masks: what are they for?
The Cardio Choc collection also includes accessories for respiratory assistance.
They do not belong to the same functional category as air filtration equipment.
Resuscitation bag-valve mask
A bag-valve mask allows certain manual ventilation interventions according to medical protocols and the rescuer's skills.
Its proper use requires hands-on training.
Cardio Choc offers, among others, disposable Laerdal models as well as a Smart Bag pediatric bag-valve mask.
Nebulizer mask
A nebulizer mask with tubing is designed for certain aerosol treatment deliveries, as medically indicated.
It is not an N95 respirator.
Oxygen mask
An O2 mask is used to deliver medical oxygen under the conditions set by its manufacturer and the appropriate protocols.
It is not intended to replace workers' respiratory protective equipment.
For oxygen delivery products, see the Oxygen therapy and medical accessories collection.
Which equipment should you choose for your setting?
Clinics and care facilities
The choice of masks depends on the tasks, infection prevention procedures and anticipated exposures.
Procedure masks and respirators may be required in different situations.
Consider the protection levels, the fit and professional practices.
Businesses and workshops
In some workplaces, respiratory contaminants may include dust, fumes, gases or vapours.
Selection requires a risk assessment and verification of the characteristics of the respirators and filters.
A universal cartridge should never be assumed to be appropriate.
First aid teams
Teams may need medical protection and CPR barriers suited to their interventions.
The equipment must match the first aiders' skills and emergency procedures.
Industrial facilities
In environments where respiratory risks are significant, the company must put in place the prevention measures and the respiratory protection program required.
Equipment must be selected for the contaminants actually present.
How do you store and maintain respiratory masks?
Disposable and reusable products are not maintained the same way.
Disposable medical masks
They must be stored in their appropriate packaging, away from factors that could compromise their integrity.
After use, they must be disposed of following the applicable procedures.
Disposable N95 respirators
They must be inspected before use.
A respirator that is damaged, soiled or whose fit is compromised must be replaced according to the manufacturer's instructions.
Do not improvise an unauthorized disinfection or reuse method.
Filters and cartridges
Filters must be replaced according to the manufacturer's recommendations and the respiratory protection program.
For gas and vapour cartridges, replacement must follow an appropriate change schedule that takes into account exposure conditions and the product's limits.
Do not routinely wait until you smell something to decide on a replacement.
Reusable respirators
Facepieces must be cleaned, inspected and stored according to the manufacturer's instructions.
Filters must not be immersed or exposed to incompatible cleaning products.
Buy masks and respiratory protective equipment from Cardio Choc
Respiratory equipment must be chosen according to its actual function: protection against splashes, particle filtration, reduction of certain chemical exposures or emergency respiratory assistance.
At Cardio Choc, we offer Level 1 and Level 2 medical masks, 3M N95 respirators, P100 filters, combination cartridges and CPR pocket masks.
Our selection meets a range of professional and first aid needs, with products that each have their own characteristics and limits.
To see the available items, explore our Masks and respiratory protection collection.
To complete your responders' equipment, also see our selection of medical supplies and personal protective equipment.
Need to choose a respirator, a compatible cartridge or CPR equipment? Contact Cardio Choc, telling us the model you are looking for and how you plan to use it. Our team can help you identify the available items and their features.
Frequently asked questions about masks and respiratory protection
What is the difference between a medical mask and an N95 respirator?
A medical mask is mainly a barrier against certain splashes and droplets. An N95 is designed to filter airborne particles when properly fitted and used.
What is the difference between Level 1 and Level 2 medical masks?
Level 2 generally corresponds to greater resistance to liquid splashes in the tests of the applicable standard. Check the certification and the exact characteristics of the product.
What does N95 mean?
N95 indicates filtration of at least 95% of the particles used in certification tests, along with a classification that is not resistant to oil-based particles.
Is the 3M 8210 respirator NIOSH-approved?
Yes. The 3M 8210 model sold by Cardio Choc is presented as a NIOSH-approved N95 respirator.
What is the valve on an N95 mask for?
The valve can make exhaling easier and reduce heat and moisture buildup. It does not mean the respirator suits every situation, especially when control of exhaled emissions is necessary.
What is the difference between N95 and P100?
The N95 offers a minimum efficiency of 95% under certification conditions and is not resistant to oil-based particles. The P100 achieves at least 99.97% and is resistant to oil-based particles, depending on its classification.
Do P100 filters protect against gases?
A P100 filter designed only for particles does not protect against all gases and vapours. For those contaminants, an appropriate cartridge may be necessary.
Is the 3M 60926 cartridge suitable for all respirators?
No. It is intended for certain compatible 3M respirator families. Check the model and the type of connector.
Does an N95 mask require a fit test?
In workplaces where fitted respiratory protection is required, a fit test is necessary under the applicable program. A seal check must also be performed each time it is used.
Can you wear an N95 respirator with a beard?
A beard on the sealing surface can prevent a proper fit. Follow the requirements of the respiratory protection program and the manufacturer's instructions.
Does a CPR pocket mask replace an N95 respirator?
No. The CPR pocket mask is a barrier device for certain rescue breaths. It is not used to filter contaminants present in ambient air.
What is the difference between an O2 mask and a respirator?
An O2 mask is used to deliver medical oxygen as indicated. A respirator is designed to protect a person against certain respiratory contaminants. The two products are not interchangeable.
How do you know when to replace a respirator cartridge?
Follow the manufacturer's instructions and the replacement schedule set by the respiratory protection program, taking into account the contaminants and conditions of use.
Defibrillators at the
best prices guaranteed
Secured
payments
Buyback
program
Free shipping on orders
over $199.99